0102030405
China JDZ9-35 Voltage Transformer Suppliers – 35kV AC Power Factory for Energy Metering and Protection
Model and its Meaning
Summarize
🛡️
Safety is paramount in high-voltage environments. Our indoor voltage transformers boast superior insulation performance and are constructed from high-quality insulating materials, providing exceptional withstand voltage. They ensure safe operation even under the harshest conditions, protecting equipment and personnel involved in power system management.
📐
One of the most compelling features is the compact design. In industries where space is at a premium, this transformer simplifies installation and maintenance. Suitable for a wide range of indoor electrical equipment, it provides a versatile solution for all power measurement needs, reducing downtime and increasing operational efficiency.
Normal Service Condition
- 🏠 Installation Site: Indoor.
- 🌡️ Ambient Temperature: Maximum air temperature 40℃; The minimum temperature is -5℃. The daily average temperature does not exceed 30℃.
- 🌫️ Atmospheric Conditions: There is no severe pollution in the atmosphere.
Technical Parameter
| Product Model | Rated Voltage Ratio (kV) | Accuracy Level or a Combination of Accuracy Levels | Rated Output (VA) | Extreme Output (VA) | Rated Insulation Level (kV) |
|---|---|---|---|---|---|
| JDZ9-35 | 35/0.1 | 0.2 | 60 | 800 | 40.5/95/200 |
| 0.5 | 120 | ||||
| 35/0.1/0.1 | 0.2/0.5 | 30/80 | 400 | ||
| 0.5/0.5 | 40/80 |
Structure and Characteristics
⚙️
This voltage transformer features a pillar-type structure and a fully enclosed epoxy resin casting process, offering excellent resistance to contamination and moisture, making it suitable for use in tropical regions. It requires no special maintenance — only regular surface cleaning.
🔌
The transformer's secondary terminals are equipped with a terminal box with holes on the front and side for easy wiring, ensuring safe and reliable access.
🔩
The baseplate is equipped with a grounding bolt and four mounting holes for easy installation.
Frequently Asked Questions (FAQ)
❓
What is the JDZ9-35 voltage transformer used for?
The JDZ9-35 is an indoor voltage transformer designed for power measurement and monitoring in high-voltage environments. It is suitable for a wide range of indoor electrical equipment and power system management applications, providing accurate voltage ratio conversion at the 35kV level.
❓
What accuracy levels are available for the JDZ9-35?
The JDZ9-35 is available in multiple accuracy levels including 0.2, 0.5, and combinations such as 0.2/0.5 and 0.5/0.5, depending on the rated voltage ratio configuration (35/0.1 or 35/0.1/0.1), allowing flexibility for different measurement precision requirements.
❓
What are the ambient temperature requirements for the JDZ9-35?
The JDZ9-35 is designed to operate in environments where the maximum air temperature does not exceed 40℃ and the minimum temperature is no lower than -5℃. Additionally, the daily average temperature should not exceed 30℃ to ensure optimal and safe performance.
❓
Is the JDZ9-35 suitable for use in humid or tropical environments?
Yes. Thanks to its fully enclosed epoxy resin casting process, the JDZ9-35 offers excellent resistance to contamination and moisture, making it well-suited for use in tropical regions or environments with high humidity levels.
❓
What maintenance does the JDZ9-35 voltage transformer require?
The JDZ9-35 requires no special maintenance. Its fully enclosed epoxy resin construction protects internal components from environmental factors. Only regular surface cleaning is recommended to maintain optimal performance and longevity.
❓
How is the JDZ9-35 installed and connected?
Installation is straightforward thanks to its compact design. The baseplate features a grounding bolt and four mounting holes for secure fixture. The secondary terminals are housed in a terminal box with access holes on both the front and side panels, allowing flexible and safe wiring connections.