0102030405
DGLR Series Isolation Switch Fuse Group - Reliable China Suppliers and Factory for AC 50Hz, Up to 1250A
🏷️ Meaning of Product Model
⚙️ Normal Working and Installation Conditions
1. The ambient air temperature shall not exceed +40℃ and not be lower than -5℃.
2. The altitude of the installation site shall not exceed 2000m.
3. Humidity: When the maximum temperature is +40℃, the relative humidity of the air does not exceed 50%. Higher relative humidity can be allowed at lower temperatures, such as reaching 90% at 20℃. Special measures should be taken for occasional condensation caused by temperature changes.
4. The pollution level of the surrounding environment is level 3.
5. The switch should be installed in a place without significant shaking, impact vibration, and invasion of rain and snow. At the same time, the installation location should be free of explosive hazardous media, and there should be no gas or dust in the media that can corrode metals and damage insulation.
🏗️ Structure Characteristics
1. The acceleration mechanism with instantaneous release of spring energy storage achieves fast connection or disconnection, independent of the speed of the operating handle, and improves the ability to extinguish arcs.
2. The shell made of unsaturated polyester glass fiber reinforced plastic (DMC) has good flame retardancy, dielectric properties, and operational safety.
3. Parallel multi break contact has self-cleaning function and reliable overcurrent and short-circuit safety protection function.
4. Can ensure that the circuit is connected or disconnected with load.
5. Replacing the melt is safe, convenient, and fast.
📊 Main Technical Parameters
Relationship between switches and fuses
| Agreed heating current lth | Equipped with fuse code | Rated current of fuse (A) |
| 63 | NT00C、NH00C | 4、6、10、16、20、25、32、40、50、63 |
| 125 | NT00、NH00 | 10、16、20、25、32、40、50、63、125 |
| 160 | NT00、NH00 | 10、16、25、32、40、50、63、80、100,125、160 |
| 250 | NT1、NH1 | 63、80、100、125、160、200、250 |
| 400 | NT2、NH2 | 160、200、250、315、400 |
| 630 | NT3、NH3 | 250、315、400、500、630 |
| 800 | NT4、NH4 | 800 |
| 1000 | NT4、NH4 | 800、1000 |
| 1250 | NT4、NH4 | 800、1000、1250 |
Main technical parameters of switches
| Model specifications | DGLR-63 | DGLR-125 | DGLR-160 | DGLR-250 | DGLR-400 | DGLR-630 | DGLR-800 | DGLR-1000 | DGLR-1250 | ||
| Agreed heating current (A) | 63 | 125 | 160 | 250 | 400 | 630 | 800 | 1000 | 1250 | ||
| Rated insulation voltage (V) | 800 | 800 | 800 | 800 | 800 | 800 | 800 | 800 | 800 | ||
| Rated impulse withstand voltage (kV) | 4 | 4 | 4 | 4 | 8 | 8 | 8 | 8 | 8 | ||
| Rated working current (A) |
380V | 63 | 125 | 160 | 250 | 400 | 630 | 800 | 1000 | 1250 | |
| 660V | 63 | 100 | 125 | 200 | 315 | 500 | 630 | 800 | 1000 | ||
| Rated making and breaking capacity(A) 1.05Ue |
AC660V,AC-23B COSФ:0.35 |
Connect | 630 | 1250 | 1600 | 2500 | 4000 | 6300 | 8000 | 10000 | 12500 |
| AC660V,AC-23B COSФ:0.35 |
Breaking | 504 | 1000 | 1280 | 2000 | 3200 | 5040 | 6400 | 8000 | 10000 | |
| Mechanical lifespan (times) | 1400 | 1400 | 1400 | 1400 | 800 | 800 | 500 | 500 | 500 | ||
| Electrical lifespan (times) | 200 | 200 | 200 | 200 | 200 | 200 | 100 | 100 | 100 | ||
| Operating Force (N) | 7.5 | 16 | 16 | 16 | 30 | 30 | 40 | 40 | 40 | ||
| Rated limit short circuit current(KA) | 50 | 50 | 50 | 50 | 50 | 50 | 100 | 100 | 100 | ||
| Use categories | AC-23B | AC-23B | AC-23B | AC-23B | AC-23B | AC-23B | AC-23B | AC-23B | AC-23B | ||
| Pollution levels | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | ||
| Installation category | III | III | III | III | III | III | III | III | III | ||
⚠️ Installation Precautions
- The contact parameters of the switch have been set by the manufacturer and cannot be adjusted freely during use.
- During the connection process between the busbar and the product, it is necessary to ensure that the distance between the busbar holes is consistent with the product wiring holes to avoid product damage caused by external forces.
📝 Ordering Notice
Customers are required to indicate the product name, model, rated current, number of poles, and quantity. For example, DGLR-400/3C11, equipped with 315A fuses, quantity of 10 units. Note: The specifications and external dimensions may change due to product improvements without further notice, and the actual product shall prevail.
❓ Frequently Asked Questions (FAQ)
💬 What are the ambient temperature requirements for installation?
The ambient air temperature should not exceed +40℃ and must not be lower than -5℃ for optimal performance.
💬 What is the maximum installation altitude for this switch?
The altitude of the installation site must not exceed 2000 meters above sea level.
💬 What material is used for the switch's shell?
The shell is made of unsaturated polyester glass fiber reinforced plastic (DMC), which provides excellent flame retardancy, dielectric properties, and operational safety.
💬 Can the circuit be connected or disconnected while under load?
Yes, the switch is designed to ensure that the circuit can be safely connected or disconnected even with a load.
💬 Does the switch require manual contact adjustment?
No, the contact parameters of the switch are pre-set by the manufacturer and cannot be adjusted freely during use.
💬 What information is required when placing an order?
Customers must provide the product name, model, rated current, number of poles, and the total quantity required.