Dual Output Switching Power Supply Dual‑Voltage SMPS for Industrial Control
Product Model Meaning

Product Introduction
This versatile dual output switching power supply provides a streamlined and efficient solution for systems demanding more than one voltage level. By integrating two independent outputs into a single, compact chassis, it eliminates the need for multiple separate power units, reducing installation time, wiring costs, and cabinet space. Its high-efficiency design ensures cool and reliable operation, contributing to long-term system stability.
Engineered for consistent performance, the unit features a universal AC input range , making it suitable for global applications. Each output channel operates reliably within a wide ambient temperature range of -25°C to +70°C. To maximize the operational lifespan of the unit, it is recommended to maintain the combined load ideally between 20% and 80% of its total rated power. Proper installation is key to achieving this longevity: ensure at least 5 cm of clearance on all sides for passive heat dissipation and avoid mounting it near other significant heat sources like transformers or large resistors.
Safety and durability are fundamental. The metal enclosure must be securely grounded to protect against electrical hazards. During wiring, carefully follow the clearly marked terminals for input and each output to prevent reverse polarity connections. It is critical to firmly tighten all terminal screws, as a loose connection can lead to dangerous overheating and potential failure. For use in challenging environments exposed to dust, moisture, or corrosive agents, selecting a model with a high IP protection rating is advised.
Every unit is rigorously validated through a 100% full load burn-in test prior to shipment, confirming its reliability under real-world operating conditions. Comprehensive protections—including safeguards against short circuit, overload, and over-voltage events on each output—are built in to protect both the power supply and your sensitive connected equipment. A clear LED power-on indicator provides instant visual confirmation of operation.
Offering a dependable 3-year warranty, this dual output power supply is a smart, robust choice for engineers and integrators looking to consolidate power delivery with confidence and efficiency.
Features
●High efficiency,high reliability,small size
●Working Temp-25℃~70℃
●100% full load burn-in test
●Protections:short circuit/over load/over voltage
●With boot display(LED Light Emitting Diode)
●3 year warranty
HDC-35
![]() |
Model |
HDC-35 |
|||
|
Input voltage range |
AC88-264VAC or DC 125-373VDC |
||||
|
DC Output |
A |
B |
|||
|
5V 4.0A |
12V 1.0A |
5V 2.2A |
24V 1.0A |
||
|
Ripple&Noise |
80mv |
120mv |
80mv |
120mv |
|
|
Efficiency |
78% |
81% |
|||
|
Over Load |
110%~150% hiccup mode,recovers automatically after fault condition is removed |
||||
|
Over Voltage |
115%~135% shut down o/p voltage,recovers automatically after fault condition is removed |
||||
|
Packing |
0.28Kg/45pcs/13.2Kg |
||||
|
Dimension |
99*97*36mm(L*W*H) |
||||

HDC-50
|
|
Model |
HDC-50 |
|||
|
Input voltage range |
AC 88-264VAC or DC 125-373VDC |
||||
|
DC Output |
A |
B |
|||
|
5V 6.0A |
12V 2.0A |
5V 4.0A |
24V 1.4A |
||
|
Ripple &Noise |
80mv |
120mv |
80mv |
120mv |
|
|
Efficiency |
78% |
81% |
|||
|
Over Load |
110%~150%hiccup mode,recovers automatically after fault condition is removed |
||||
|
Over Voltage |
115%~135%shut down o/p voltage,recovers automatically after fault condition is removed |
||||
|
Packing |
0.39Kg/45pcs/18.5Kg |
||||
|
Dimension |
129*97*38mm(L*W*H) |
||||

HDC-75
|
|
Model |
HDC-75 |
|||
|
Input voltage range |
AC 88-264VAC or DC 125-373VDC |
||||
|
DC Output |
A |
B |
|||
|
5V 7.0A |
12V 3.0A |
5V 5.0A |
24V 2.0A |
||
|
Ripple &Noise |
80mv |
120mv |
80mv |
120mv |
|
|
Efficiency |
78% |
81% |
|||
|
Over Load |
110%~150% hiccup mode,recovers automatically after fault condition is removed |
||||
|
Over Voltage |
115%~135% shut down o/p voltage,recovers automatically after fault condition is removed |
||||
|
Packing |
0.42Kg/30pcs/13.2Kg |
||||
|
Dimension |
159*97*38mm(L*W*H) |
||||

HDC-100
|
|
Model |
HDC-100 |
|||
|
Input voltage range |
AC90-132/180-264VAC with switch selection;Or DC 254-373VDC |
||||
|
DC Output |
A |
B |
|||
|
5V 10A |
12V 4.0A |
5V 10A |
24V 2.0A |
||
|
Ripple&Noise |
80mv |
120mv |
80mv |
120mv |
|
|
Efficiency |
78% |
81% |
|||
|
Over Load |
110%~150% hiccup mode,recovers automatically after fault condition is removed |
||||
|
Over Voltage |
115%~135% hiccup mode,recovers automatically after fault condition is removed |
||||
|
Packing |
0.54Kg/30pcs/16.8Kg |
||||
|
Dimension |
199*97*38mm(L*W*H) |
||||

HDC-150
|
|
Model |
HDC-150 |
|||
|
Input voltage range |
AC90-132/180-264VAC with switch selection;Or DC 254-373VDC |
||||
|
DC Output |
A |
B |
|||
|
5V15A |
12V6.0A |
5V15A |
24V3.2A |
||
|
Ripple&Noise |
80mv |
120mv |
80mv |
120mv |
|
|
Efficiency |
78% |
81% |
|||
|
Over Load |
110%~150% hiccup mode,recovers automatically after fault condition is removed |
||||
|
Over Voltage |
115%~135% hiccup mode,recovers automatically after fault condition is removed |
||||
|
Packing |
0.58Kg/30pcs/18Kg |
||||
|
Dimension |
199*97*38mm(L*WH) |
||||

HDC-200
|
|
Model |
HDC-200 |
|||
|
Input voltage range |
AC90-132/180-264VAC with switch selection;Or DC 254-373VDC |
||||
|
DC Output |
A |
B |
|||
|
5V 20A |
12V 8.3A |
5V 20A |
24V 4.2A |
||
|
Ripple &Noise |
80mv |
120mv |
80mv |
120mv |
|
|
Efficiency |
78% |
81% |
|||
|
Over Load |
110%~150% current limiting,delay shut down o/p voltage,re-power on to recover |
||||
|
Over Voltage |
115%~135% shut down o/p voltage, recovers automatically after fault condition is removed |
||||
|
Packing |
0.69Kg/22pcs/15.7Kg |
||||
|
Dimension |
199*110*50mm(L*W*H) |
||||

HDC-350
|
|
Model |
HDC-350 |
|
|
Input voltage range |
AC90-132/180-264VAC with switch selection;Or DC 254-373VDC |
||
|
DC Output |
A |
||
|
12V15A |
24V7A |
||
|
Ripple &Noise |
80mv |
200mv |
|
|
Efficiency |
81% |
||
|
Over Load |
110%~150% current limiting,delay shut down o/p voltage,re-power on to recover |
||
|
Over Voltage |
115%~135% shut down o/p voltage,recovers automatically after fault condition is removed |
||
|
Packing |
0.85Kg/12pcs/10.6Kg |
||
|
Dimension |
215*115*50mm(L*W*H) |
||

HTC-35
|
|
Model |
HTC-35 |
|||||
|
Input voltage range |
AC 88-264VAC or DC 125-373VDC |
||||||
|
DC Output |
A |
B |
|||||
|
5V 3.0A |
12V 1.0A |
-5V 0.5A |
5V 3.0A |
12V 1.0A |
-12V 0.5A |
||
|
Ripple&Noise |
80mv |
120mv |
120mv |
80mv |
120mv |
120mv |
|
|
Efficiency |
78% |
79% |
|||||
|
Over Load |
110%~150% hiccup mode,recovers automatically after fault condition is removed |
||||||
|
Over Voltage |
115%~135% shut down o/p voltage,recovers automatically after fault condition is removed |
||||||
|
Packing |
0.28Kg/45pcs/13.2Kg |
||||||
|
Dimension |
99*97*36mm(L*W*H) |
||||||

HTC-50
|
|
Model |
HTC-50 |
|||||
|
Input voltage range |
AC88-264VAC or DC 125-373VDC |
||||||
|
DC Output |
A |
B |
|||||
|
5V 4.0A |
12V 2.0A |
-5V 0.5A |
5V 4.0A |
12V 2.0A |
-12V 0.5A |
||
|
Ripple &Noise |
80mv |
120mv |
120mv |
80mv |
120mv |
120mv |
|
|
Efficiency |
78% |
79% |
|||||
|
Over Load |
110%~150% hiccup mode,recovers automatically after fault condition is removed |
||||||
|
Over Voltage |
115%~135% shut down o/p voltage,recovers automatically after fault condition is removed |
||||||
|
Packing |
0.39Kg/45pcs/18.5Kg |
||||||
|
Dimension |
129*97*38mm(L*W*H) |
||||||

HTC-75
|
|
Model |
HTC-75 |
|||||
|
Input voltage range |
AC 88-264VAC or DC 125-373VDC |
||||||
|
DC Output |
A |
B |
|||||
|
5V 6.0A |
12V 3.0A |
-5V 0.5A |
5V 5.0A |
12V 2.8A |
-12V 0.5A |
||
|
Ripple&Noise |
80mv |
120mv |
120mv |
80mv |
120mv |
120mv |
|
|
Efficiency |
78% |
79% |
|||||
|
Over Load |
110%~150% hiccup mode,recovers automatically after fault condition is removed |
||||||
|
Over Voltage |
115%~135% shut down o/p voltage,recovers automatically after fault condition is removed |
||||||
|
Packing |
0.42Kg/30pcs/13.2Kg |
||||||
|
Dimension |
159*97*38mm(L*W*H) |
||||||

HT-100
|
|
Model |
HT-100 |
|||||
|
Input voltage range |
AC90-132/180-264VAC with switch selection;OrDC 254-373VDC |
||||||
|
DC Output |
C |
D |
|||||
|
5V 10A |
15V 2.5A |
-15V 1A |
5V 6A |
12V 2A |
24V 2A |
||
|
Ripple&Noise |
80mv |
150mv |
150mv |
80mv |
150mv |
150mv |
|
|
Efficiency |
78% |
81% |
|||||
|
Over Load |
110%~150% shut down o/p voltage,re-power on to recover |
||||||
|
Over Voltage |
115%~135% shut down o/p voltage,re-power on to recover |
||||||
|
Packing |
0.72Kg/22pcs/16.5Kg |
||||||
|
Dimension |
199*110*50mm(L*W*H) |
||||||

Q-60
|
|
Model |
Q-60 |
|||||||
|
Input voltage range |
AC 88-264VAC or DC 125-373VDC |
||||||||
|
DC Output |
B |
C |
|||||||
|
5V 5.5A |
12V 2.0A |
-5V 0.5A |
-12V 0.5A |
5V 5.5A |
15V 1.5A |
-5V 0.5A |
-15V 0.5A |
||
|
Ripple&Noise |
100mv |
120mv |
100mv |
120mv |
100mv |
120mv |
100mv |
120mv |
|
|
Efficiency |
70% |
72% |
|||||||
|
Over Load |
110%~150% hiccup mode, recovers automatically after fault condition is removed |
||||||||
|
Over Voltage |
115%~135% shut down o/p voltage, recovers automatically after fault condition is removed |
||||||||
|
Packing |
0.56Kg/30pcs/17.3Kg |
||||||||
|
Dimension |
159*97*38mm (L*W*H) |
||||||||

Q-120
|
|
Model |
Q-120 |
|||||||
|
Input voltage range |
AC 90-132/180-264VAC with switch selection; Or DC 254-373VDC |
||||||||
|
DC Output |
B |
C |
|||||||
|
5V 11A |
12V 4.0A |
-5V 1.0A |
-12V 1.0A |
5V 10A |
15V 3.5A |
-5V 1.0A |
-15V 1.0A |
||
|
Ripple&Noise |
80mv |
120mv |
80mv |
120mv |
80mv |
150mv |
80mv |
150mv |
|
|
Efficiency |
70% |
72% |
|||||||
|
Over Load |
110%~150% shut down o/p voltage, re-power on to recover |
||||||||
|
Over Voltage |
115%~135% shut down o/p voltage, re-power on to recover |
||||||||
|
Packing |
0.86Kg/22pcs/19.2Kg |
||||||||
|
Dimension |
199*110*50mm(L*W*H) |
||||||||


JDG4-0.5 type voltage transformer,Accuracy class 0.5,designed for voltage measurement and relay protection in indoor AC circuits