JDZ(18)-3,6,10 3‑10kV Indoor Cast Resin Voltage Transformer

The JDZ(18)-3, 6, and 10 type voltage transformers are suitable for AC power systems with a rated frequency of 50Hz or 60Hz and a rated voltage of 3-10kV, and are used for electric energy metering, voltage measurement, and relay protection.
The product execution standards are GB20840.1-2010 and GB20840.3-2013.

    Model and its meaning

    JDZ(18)-3、6、10.jpg

    Summarize

    Voltage transformers (VTs) play a vital role in the operation and safety of AC power systems, particularly those operating at a rated frequency of 50Hz or 60Hz and with a rated voltage range of 3-10kV. These devices are designed for energy metering, voltage measurement, and relay protection, ensuring efficient and safe power system operation. Voltage transformers comply with GB20840.1-2010 and GB20840.3-2013 standards, providing reliable solutions for a variety of applications in industrial and commercial environments.

    Normal service condition

    Installation site: Indoor

    Ambient temperature: The maximum temperature is 40℃ , the minimum temperature is -5℃ , and the daily average temperature does not exceed 30℃ .

    Atmospheric conditions: There is no severe pollution in the atmosphere.

    Technical parameter

    Product
    model

    Rated voltage
    ratio

    Accuracy
    level

    Rated
    output(VA)

    Extreme
    output(VA)

    Rated insulation
    level(KV)

    JDZ(18)-3

    3/0.1

    0.2

    15

    200

    3.6/25/40

    0.5

    30

    JDZ(18)-6

    6/0.1

    0.2

    15

    200

    7.2/32/60

    0.5

    30

    JDZ(18)-10

    10/0.1

    0.2

    15

    200

    12/42/75

    0.5

    30

    JDZ(18)-3

    3/0.1/0.22

    0.2/3

    15/500

    600

    3.6/25/40

    0.5/3

    30/500

    JDZ(18)-6

    6/0.1/0.22

    0.2/3

    15/500

    600

    7.2/32/60

    0.5/3

    30/500

    JDZ(18)-10

    10/0.1/0.22

    0.2/3

    15/500

    600

    12/42/75

    0.5/3

    30/500

    Structure and characteristics

    This series of voltage transformers adopt a pillar structure and are fully enclosed with epoxy resin by epoxy casting. They are resistant to pollution and moisture and are also suitable for use in tropical regions. The transformers do not require special maintenance; only regular cleaning of surface dirt is needed. Terminal boxes are installed at the secondary output terminals of the transformers. There is one hole on the front and one on the side of the terminal box to cooperate with the output terminals for leadout wiring, which is safe and reliable. There are grounding bolts and six installation holes for installation on the product base plate.

    jdz-18-3-6-10-2.jpg