LMZC‑10 10kV Through‑Hole Current Transformer for Gas‑Insulated RMU
Model and its meaning

Summarize
Advantages of LMZC-10 Special through-hole current transformer for gas-filled cabinets
Specialized Design: The LMZC-10 current transformer is specifically designed for gas-insulated switchgear applications, perfectly adapting to the structure and operating environment of gas-insulated switchgear to ensure optimal installation and performance.
High-precision measurement: The instrument's transformer has excellent measurement accuracy, which can accurately reflect current changes and ensure that the monitoring and protection requirements of the power system are met.
Pass-through structure: The unique pass-through design makes installation more convenient, especially suitable for gas cabinets with limited space, saving installation space and time.
Excellent insulation performance: Made of high-quality insulation materials, it has excellent pressure resistance, ensuring safe operation in high-pressure environments and reducing the risk of equipment failure.
Technical parameter
Rated frequency: 50Hz or 60Hz, suitable for major global power system standards, ensuring wide compatibility and stability of the equipment.
Rated secondary current: 5A or 1A, providing flexible current output options to meet the needs of different application scenarios.
Rated short-time thermal current: 40kA, 2s, ensuring that the equipment can withstand high current surges in a short period of time and protecting the safe operation of the system.
Rated continuous thermal current: 1200%In, indicating that the equipment has a high tolerance under normal operating conditions and can cope with sudden load changes.
The power factor of the load is: COSΦ < P = 0.8 (lagging), which ensures that the equipment can effectively convert and utilize electrical energy during operation and improve the overall efficiency of the system.
Instrument safety factor (measurement): FS < 10, indicating that the equipment has good safety and reliability during the measurement process and can effectively prevent overload.
Accurate limit system (protection): 10P10, 10P15, 10P20, providing multiple protection level options to meet the safety requirements of different power systems and ensure the accuracy and stability of equipment under various operating conditions.
|
Model |
Purpose |
Measure the |
Protect the |
Double-winding |
|||||||
|
Stabilize the |
Accuracy level and |
Accuracy level and |
Accuracy level and |
||||||||
|
0.2s |
0.2 |
0.5 |
10P5 |
10P10 |
10P15 |
0.5 |
1 |
10P10 |
10P5 |
||
|
LMZC-10-1 |
75 |
– |
– |
– |
– |
– |
– |
– |
– |
– |
– |
|
100 |
– |
– |
– |
2.5 |
– |
– |
– |
– |
– |
– |
|
|
150 |
2.5 |
2.5 |
2.5 |
2.5 |
– |
– |
– |
– |
– |
– |
|
|
200 |
2.5 |
2.5 |
2.5 |
3.75 |
– |
– |
– |
– |
– |
– |
|
|
300 |
5 |
5 |
5 |
5 |
– |
– |
– |
– |
– |
– |
|
|
400 |
5 |
5 |
5 |
5 |
2.5 |
– |
– |
– |
– |
– |
|
|
500 |
10 |
10 |
10 |
7.5 |
2.5 |
– |
– |
– |
– |
– |
|
|
600 |
10 |
10 |
10 |
10 |
5 |
– |
– |
– |
– |
– |
|
|
LMZC-10-2 |
50 |
– |
– |
2.5 |
– |
– |
– |
– |
– |
– |
– |
|
75 |
2.5 |
3.75 |
3.75 |
2.5 |
– |
– |
– |
– |
– |
– |
|
|
100 |
5 |
5 |
5 |
5 |
2.5 |
1.5 |
– |
– |
– |
– |
|
|
150 |
5 |
5 |
5 |
7.5 |
3.75 |
1.5 |
– |
– |
– |
– |
|
|
200 |
7.5 |
7.5 |
7.5 |
10 |
5 |
2.5 |
5 |
5 |
– |
2.5 |
|
|
300 |
10 |
10 |
15 |
15 |
7.5 |
5 |
7.5 |
7.5 |
– |
3.75 |
|
|
400 |
15 |
20 |
20 |
20 |
10 |
7.5 |
7.5 |
7.5 |
2.5 |
5 |
|
|
500 |
20 |
25 |
25 |
25 |
10 |
7.5 |
10 |
10 |
2.5 |
5 |
|
|
600 |
20 |
25 |
30 |
25 |
10 |
7.5 |
10 |
10 |
3.75 |
7.5 |
|