LSY‑3‑10/127 10kV Three‑Phase Combined Zero‑Sequence CT for Medium Voltage Switchgear
Model and its meaning

Summarize
The LSY-3-10/127 features a three-phase integrated design, combining current measurement, protection, and switching functions into a compact device. This integration simplifies installation and wiring, significantly improving the overall reliability of the power system. By reducing the number of required components, the LSY-3-10/127 minimizes potential points of failure, thereby enhancing system robustness and lifespan.
One of the most notable features of the LSY-3-10/127 is its high-precision measurement capability. This transformer is designed to accurately convert large current signals into easily manageable small current signals, thereby ensuring measurement accuracy in power systems. This accuracy is crucial for a wide range of applications, including power monitoring, protection, and control, as even minute deviations can lead to serious operational problems. Therefore, the LSY-3-10/127 is ideal for professionals seeking reliable and accurate current measurement in power systems.
Durability is another key feature of the LSY-3-10/127. This three-phase integrated current transformer is manufactured using high-quality materials, exhibiting excellent corrosion resistance and high-temperature performance. These characteristics enable it to operate stably in harsh environmental conditions, making it suitable for a wide range of applications. Whether deployed in industrial or outdoor environments, the LSY-3-10/127 can withstand demanding operating conditions.
The versatility of the LSY-3-10/127 is also reflected in its compatibility with 50Hz and 60Hz power systems. This adaptability allows the transformer to meet the standards of different countries and regions, making it a globally applicable solution. As power systems continue to evolve, the ability to adapt to different frequency standards is crucial for ensuring seamless integration and functionality across a wide range of applications.
Technical parameter
Rated frequency: 50Hz or 60Hz
Rated secondary current: 5A or 1A
Rated short-term thermal current: 40kA,2 seconds
Rated continuous thermal current: 1200%In
Power factor of load: COC < P=0.8 (lag)
Instrument security factor (measurement) : FS < 10
Accurate limit system (protection) : 10P10,10P15,10P20
|
Model |
Purpose |
Measure the |
Protect the |
Double-winding |
|||||||
|
Stabilize |
Accuracy level and |
Accuracy level and |
Accuracy level and |
||||||||
|
0.2s |
0.2 |
0.5 |
10P5 |
10P10 |
10P15 |
0.5 |
1 |
10P10 |
10P5 |
||
|
LSY-127 |
75 |
– |
– |
1 |
– |
– |
– |
– |
1 |
– |
– |
|
100 |
– |
– |
2.5 |
– |
– |
– |
– |
1 |
– |
– |
|
|
150 |
– |
– |
2.5 |
2.5 |
– |
– |
– |
1.5 |
– |
– |
|
|
200 |
– |
2.5 |
2.5 |
5 |
– |
– |
– |
2.5 |
– |
5 |
|
|
300 |
2.5 |
2.5 |
5 |
5 |
– |
– |
– |
2.5 |
– |
5 |
|
|
400 |
5 |
5 |
5 |
7.5 |
– |
– |
– |
5 |
– |
7.5 |
|
|
500 |
5 |
5 |
10 |
10 |
– |
– |
– |
5 |
– |
10 |
|
|
600 |
5 |
10 |
10 |
10 |
– |
– |
– |
5 |
– |
10 |
|
|
800 |
10 |
10 |
10 |
10 |
– |
– |
– |
5 |
– |
10 |
|


JDG4-0.5 type voltage transformer,Accuracy class 0.5,designed for voltage measurement and relay protection in indoor AC circuits