LZZBJ9-12/150b/2(4) 12kV Indoor Cast Resin Current Transformer | MV CT for Switchgear Protection and Metering
Model and its meaning
Summarize
The LZZBJ9-12/150b/2(4) series current transformers are suitable for power systems with a rated frequency of 50Hz or 60Hz and a rated voltage of 10kV, and are used for electric energy metering, current measurement and relay protection.
One of the most attractive features of the LZZBJ9-12/150b/2(4) current transformer is its maintenance-free operation. In industries where downtime can result in significant financial losses, the ability to deploy a transformer that requires no special maintenance is a significant advantage. This feature not only reduces operating costs but also improves overall power system reliability. Users can be confident that the LZZ-10 current transformer will perform consistently without the need for frequent inspection or repair, enabling a more streamlined approach to energy management.
Normal service condition
Installation site: Indoor.
Ambient temperature: Maximum air temperature 40℃ ; The minimum temperature is -5℃ . The daily average temperature does not exceed 30℃.
Atmospheric conditions: There is no severe pollution in the atmosphere.
Technical parameter
LZZBJ9-12/150b/2 type current transformer Technical Parameter Table
|
Product |
Rated primary |
Accuracy level |
Rated |
Rated short-term |
Rated dynamic |
|
LZZBJ9- |
5 |
0.2/10P10 |
10/15 |
0.5 |
1.25 |
|
10 |
1 |
2.5 |
|||
|
15 |
1.5 |
3.75 |
|||
|
20 |
2 |
5 |
|||
|
30 |
3 |
7.5 |
|||
|
40 |
4 |
10 |
|||
|
50 |
5 |
12.5 |
|||
|
75 |
7.5 |
18.75 |
|||
|
100 |
10 |
25 |
|||
|
150 |
15 |
37.5 |
|||
|
200 |
21 |
52.5 |
|||
|
300 |
24.5 |
61.25 |
|||
|
400 |
32 |
80 |
|||
|
500 |
0.2(0.5)/10P10 |
10/15 |
32 |
80 |
|
|
600 |
32 |
80 |
|||
|
800 |
0.2/10P10 |
15/20 |
50 |
125 |
|
|
1000 |
50 |
125 |
|||
|
1200 |
50 |
125 |
|||
|
1250 |
50 |
125 |
Rated secondary current: 5A or 1A, rated insulation level: 12/42/75kV.
LZZBJ9-12/150b/4 type current transformer Technical Parameter Table
|
Product |
Rated primary |
Accuracy level |
Rated |
Rated short-term |
Rated dynamic |
|
LZZBJ9- |
5 |
0.2/0.2/5P10 |
10/10/15 |
0.6 |
1.5 |
|
10 |
1.2 |
3 |
|||
|
15 |
1.8 |
4.5 |
|||
|
20 |
2.4 |
6 |
|||
|
30 |
3.6 |
9 |
|||
|
40 |
4.8 |
12 |
|||
|
50 |
6 |
15 |
|||
|
75 |
9 |
22.5 |
|||
|
100 |
12 |
30 |
|||
|
150 |
21 |
52.5 |
|||
|
200 |
21 |
52.5 |
|||
|
300 |
0.2/0.2/5P10 |
10/10/15 |
45 |
112.5 |
|
|
400 |
|||||
|
500 |
32 |
80 |
|||
|
600 |
|||||
|
800 |
|||||
|
1000 |
0.2/0.2/5P10 |
10/10/20 |
50 |
125 |
|
|
1200 |
|||||
|
1250 |
Structure and characteristics
This series of current transformers are of fully enclosed structure with epoxy resin casting, featuring excellent insulation performance and moisture-proof capability. The product features a compact structure, small size, light weight and easy surface cleaning. A terminal box is installed at the secondary output terminal, which is safe and reliable. There are grounding bolts and six installation holes for installation on the product base plate.



JDG4-0.5 type voltage transformer,Accuracy class 0.5,designed for voltage measurement and relay protection in indoor AC circuits