Zhejiang Donghua Electrical Appliance Co., Ltd.
Leave Your Message
Products Categories
Featured Products

LZZBW‑35A 35kV Instrument CT Epoxy Cast Current Transformer

As a key measurement and protection component in power systems, current transformers (CTs) offer significant advantages in many aspects due to their unique structure and operating principle. They are widely used in various links such as power generation, transmission, distribution and consumption. The insulation level is crucial for protecting transformers and their connected equipment from potential electrical faults, thereby improving the overall safety of electrical systems.
The product implementation standards are GB20840.1-2010 and GB20840.2-2014.

    Model and its meaning

    LZZBW-35A.jpg

    Summarize

    The voltage on the high-voltage side of power systems (such as 10kV, 110kV, and 220kV), is extremely high. Directly measuring or connecting these voltages to control and protection devices poses serious safety risks. A current transformer's primary winding is connected in series with the high-voltage circuit, while its secondary winding is connected to measuring instruments (such as ammeters) and relay protection devices on the low-voltage side. Current signals are transmitted through the principle of electromagnetic induction. Reliable insulation between the primary and secondary sides effectively blocks high-voltage hazards, preventing them from entering the low-voltage side and potentially damaging equipment or causing electric shock.Achieve electrical isolation between high voltage and low voltage to ensure the safety of personnel and equipment

    The LZZBW-35A current transformer is designed for AC power systems with a rated voltage of 35kV and a rated frequency of 50Hz/60Hz. Its core applications include energy metering, current monitoring, and relay protection.

    Normal service condition

    • Installation location: must be placed outdoors, not indoors.
    • Temperature requirements: The maximum ambient temperature cannot exceed 40℃, the minimum cannot be lower than -25℃, and the average temperature of the day must be controlled within 30℃.
    • Air conditions: The air in the environment must be clean, without serious dust, dirt and other impurities.

    Technical parameter

    LZZBW-35A current transformer technical parameter table

    Product
    model

    Rated primary
    current

    Accuracy level
    combination

    Rated output

    Rated short-term
    thermal current

    Rated dynamic
    stability current

    0.2

    0.5

    5P20

    LZZBW-35A

    20-100

    0.2/5P20
    0.5/5P20

    10

    15

    15

    150lin

    375lin

    150-200

    31.5

    80

    300-500

    31.5/2

    600-1200

    15

    30

    20

    31.5/4

    1500

    20

    40

    30

    40/4

    125