S Single Output Switching Power Supply,85~264 VAC AC to DC,Self-excited Switching Power Supply
Product Model Meaning

Product Introduction
This switching power supply serves as a reliable, compact heart for your DC power needs. Engineered for high efficiency and reliability, its small size saves valuable space in control cabinets without sacrificing performance. The unit is built to operate within a wide ambient temperature range of -25°C to +70°C, providing flexibility for various installation environments. For optimal service life, it is recommended to avoid sustained operation at the upper limits of this range and ensure adequate ventilation, as a consistent rule of thumb is that component lifespan can decrease significantly with elevated operating temperatures.
Every unit undergoes a rigorous 100% full load burn-in test before leaving the factory, ensuring reliability from the moment it is installed. A suite of built-in protections including safeguards against short circuit, overload, and over-voltage conditions actively shields both the power supply and your valuable connected equipment from electrical faults. A simple yet effective boot display LED offers immediate visual confirmation of its operational status.
To ensure the power supply performs as intended over its long service life, proper installation is key. The device requires a compatible input voltage . For cooling and longevity, allow at least 5 cm of clearance on all sides, particularly away from other heat-producing components. It should be installed in a clean, dry location, with special IP65-or-higher rated versions recommended for damp, dusty, or outdoor environments. Safety is paramount: the metal casing must always be reliably grounded. During wiring, carefully follow the terminal markings for input and output connections and ensure all terminal screws are securely tightened to prevent dangerous overheating due to poor contacts.
Backed by a 3-year warranty, this power supply combines practical design with durable construction for a steadfast power solution in a multitude of applications.
Features
●High efficiency,high reliability,small size
●Working Temp-25℃~70℃
●100% full load burn-in test
●Protections:short circuit/over load/over voltage
●With boot display(LED Light Emitting Diode)
●3 year warranty
SKS-15
![]() |
Model |
SKS-15 |
||
|
Input voltage range |
AC 85-132/170-264VAC with switch selection;Or DC 254-373VDC |
|||
|
DC Output |
5.0V 3.0A |
12V 1.3A |
24V 0.7A |
|
|
Ripple&Noise |
50mv |
100mv |
120mv |
|
|
Efficiency |
72% |
76% |
80% |
|
|
Over Load |
110%~150%current limiting,recovers automatically after fault condition is removed |
|||
|
Over Voltage |
/ |
|||
|
Packing |
0.25Kg/45pcs/11.9Kg |
|||
|
Dimension |
99*97*36mm(L*W*H) |
|||

SKS-25
![]() |
Model |
SKS-25 |
||
|
Input voltage range |
AC 85-264VAC or DC 125-373VDC |
|||
|
DC Output |
5.0V 5.0A |
12V 2.1A |
24V 1.1A |
|
|
Ripple&Noise |
50mv |
100mv |
120mv |
|
|
Efficiency |
72% |
76% |
80% |
|
|
Over Load |
110%~150%current limiting,recovers automatically after fault condition is removed |
|||
|
Over Voltage |
115%~135%hiccup mode,recovers automatically after fault condition is removed |
|||
|
Packing |
0.29Kg/45pcs/13.8Kg |
|||
|
Dimension |
99*97*36mm(L*W*H) |
|||

SKS-35
![]() |
Model |
SKS-35 |
||
|
Input voltage range |
AC 85-132/170-264VACwith switch selection;Or DC 254-373VDC |
|||
|
DC Output |
5.0V 7.0A |
12V 3.0A |
24V 1.5A |
|
|
Ripple &Noise |
50mv |
100mv |
120mv |
|
|
Efficiency |
70% |
76% |
78% |
|
|
Over Load |
110%~150%current limiting,recovers automatically after fault condition is removed |
|||
|
Over Voltage |
/ |
|||
|
Packing |
0.34Kg/45pcs/15.9Kg |
|||
|
Dimension |
129*97*38mm(L*W*H) |
|||

SKS-50
![]() |
Model |
SKS-50 |
||
|
Input voltage range |
AC 85-132/170-264VAC with switch selection;Or DC 254-373VDC |
|||
|
DC Output |
5.0V 10A |
12V 4.2A |
24V 2.1A |
|
|
Ripple&Noise |
80mv |
100mv |
120mv |
|
|
Efficiency |
70% |
76% |
78% |
|
|
Over Load |
110%~150%current limiting,recovers automatically after fault condition is removed |
|||
|
Over Voltage |
/ |
|||
|
Packing |
0.42Kg/30pcs/13.3Kg |
|||
|
Dimension |
159*97*38mm(L*W*H) |
|||

SKS-60
![]() |
Model |
SKS-60 |
||
|
Input voltage range |
AC85-264VAC or DC 125-373VDC |
|||
|
DC Output |
5.0V 12A |
12V 5.0A |
24V 2.5A |
|
|
Ripple&Noise |
120mv |
120mv |
150mv |
|
|
Efficiency |
70% |
76% |
79% |
|
|
Over Load |
110%~150%current limiting,recovers automatically after fault condition is removed |
|||
|
Over Voltage |
115%~135%hiccup mode,recovers automatically after fault condition is removed |
|||
|
Packing |
0.41Kg/30pcs/13Kg |
|||
|
Dimension |
159*97*38mm(L*W*H) |
|||

HS-100B
![]() |
Model |
HS-100B |
||
|
Input voltage range |
AC88-132/176-264VACwith switch selection;Or DC 254-373VDC |
|||
|
DC Output |
5.0V 18A |
12V 8.3A |
24V 4.2A |
|
|
Ripple &Noise |
80mv |
100mv |
100mv |
|
|
Efficiency |
80% |
83% |
85% |
|
|
Over Load |
110%~150%hiccup mode,recovers automatically after fault condition is removed |
|||
|
Over Voltage |
115%~135%hiccup mode,recovers automatically after fault condition is removed |
|||
|
Packing |
0.44Kg/30pcs/13.7Kg |
|||
|
Dimension |
159*97*38mm(L*W*H) |
|||

SKS-100
![]() |
Model |
SKS-100 |
||
|
Input voltage range |
AC 88-132/176-264VAC with switch selection;Or DC 254-373VDC |
|||
|
DC Output |
5.0V 20A |
12V 8.5A |
24V 4.5A |
|
|
Ripple&Noise |
80mv |
120mv |
150mv |
|
|
Efficiency |
78% |
81% |
84% |
|
|
Over Load |
110%~150%shut down o/p voltage,re-power on to recover |
|||
|
Over Voltage |
/ |
|||
|
Packing |
0.53Kg/30pcs/16.6Kg |
|||
|
Dimension |
199*97*38mm(L*WH) |
|||

HS-150B
![]() |
Model |
HS-150B |
||
|
Input voltage range |
AC90-132/180-264VAC with switch selection;Or DC 254-373VDC |
|||
|
DC Output |
5.0V 25A |
12V 12.5A |
24V 6.5A |
|
|
Ripple &Noise |
100mv |
120mv |
120mv |
|
|
Efficiency |
80% |
83% |
86% |
|
|
Over Load |
110%~150%hiccup mode,recovers automatically after fault condition is removed |
|||
|
Over Voltage |
115%~135%hiccup mode,recovers automatically after fault condition is removed |
|||
|
Packing |
0.54Kg/30pcs/16.8Kg |
|||
|
Dimension |
199*97*38mm(L*W*H) |
|||

SKS-145
![]() |
Model |
SKS-145 |
||
|
Input voltage range |
AC 88-132/176-264VAC with switch selection;Or DC 254-373VDC |
|||
|
DC Output |
5.0V 25A |
12V 12A |
24V 6.0A |
|
|
Ripple &Noise |
100mv |
120mv |
150mv |
|
|
Efficiency |
78% |
81% |
84% |
|
|
Over Load |
110%~150%shut down o/p voltage,re-power on to recover |
|||
|
Over Voltage |
115%~135%shut down o/p voltage,re-power on to recover |
|||
|
Packing |
0.54Kg/30pcs/16.8Kg |
|||
|
Dimension |
199*97*38mm(L*W*H) |
|||

HS-200T
![]() |
Model |
HS-200T |
||
|
Input voltage range |
AC90-132/180-264VAC with switch selection;Or DC 254-373VDC |
|||
|
DC Output |
5.0V 40A |
12V 16.5A |
24V 8.3A |
|
|
Ripple&Noise |
150mv |
150mv |
150mv |
|
|
Efficiency |
78% |
82% |
84% |
|
|
Over Load |
110%~150%shut down o/p voltage,re-power on to recover |
|||
|
Over Voltage |
/ |
|||
|
Packing |
0.69Kg/22pcs/15.6Kg |
|||
|
Dimension |
199*110*50mm(L*W*H) |
|||

HS-201T
![]() |
Model |
HS-201T |
||
|
Input voltage range |
AC90-132/180-264VAC with switch selection;Or DC 254-373VDC |
|||
|
DC Output |
5.0V 30A |
12V 16.5A |
24V 8.3A |
|
|
Ripple&Noise |
150mv |
150mv |
150mv |
|
|
Efficiency |
74% |
80% |
83% |
|
|
Over Load |
110%~150%current limiting,recovers automatically after fault condition is removed |
|||
|
Over Voltage |
115%~135%voltage limiting,recovers automatically after fault condition is removed |
|||
|
Packing |
0.69Kg/12pcs/8.7Kg |
|||
|
Dimension |
215*115*50mm(L*W*H) |
|||

HS-250T
![]() |
Model |
HS-250T |
||
|
Input voltage range |
AC90-132/180-264VAC with switch selection;Or DC 254-373VDC |
|||
|
DC Output |
5.0V 40A |
12V 20A |
24V 10A |
|
|
Ripple &Noise |
150mv |
150mv |
150mv |
|
|
Efficiency |
74% |
80% |
83% |
|
|
Over Load |
110%~150%current limiting,recovers automatically after fault condition is removed |
|||
|
Over Voltage |
115%~135%voltage limiting,recovers automatically after fault condition is removed |
|||
|
Packing |
0.76Kg/12pcs/9.5Kg |
|||
|
Dimension |
215*115*50mm(L*W*H) |
|||

HS-350
![]() |
Model |
HS-350 |
||
|
Input voltage range |
AC90-132/180-264VAC with switch selection;Or DC 254-373VDC |
|||
|
DC Output |
5.0V 45A |
12V 29A |
24V 14.6A |
|
|
Ripple&Noise |
150mv |
150mv |
150mv |
|
|
Efficiency |
74% |
79% |
81% |
|
|
Over Load |
110%~150%hiccup mode,recovers automatically after fault condition is removed |
|||
|
Over Voltage |
115%~135%voltage limiting,recovers automatically after fault condition is removed |
|||
|
Packing |
0.82Kg/12pcs/10.3Kg |
|||
|
Dimension |
215*115*50mm(L*W*H) |
|||

HS-480
![]() |
Model |
HS-480 |
|
|
Input voltage range |
AC90-132/180-264VAC with switch selection;Or DC 254-373VDC |
||
|
DC Output |
12V 40A |
24V 20A |
|
|
Ripple&Noise |
120mv |
240mv |
|
|
Eficiency |
85% |
87% |
|
|
Over Load |
110%~150%hiccup mode,recovers automatically after fault condition is removed |
||
|
Over Voltage |
115%~135%shut down o/p voltage,re-power on to recover |
||
|
Packing |
0.82Kg/12pcs/10.3Kg |
||
|
Dimension |
215*115*50mm(L*W*H) |
||

HS-500
![]() |
Model |
HS-500 |
|
|
Input voltage range |
AC 180-264VAC or DC 254-373VDC |
||
|
DC Output |
12V 40A |
24V 20A |
|
|
Ripple &Noise |
240mv |
240mv |
|
|
Efficiency |
83% |
85% |
|
|
Over Load |
110%~150%hiccup mode,recovers automatically after fault condition is removed |
||
|
Over Voltage |
115%~135%hiccup mode,recovers automatically after fault condition is removed |
||
|
Packing |
1.16Kg/8pcs/9.7Kg |
||
|
Dimension |
240*124*65mm(L*W*H) |
||

HS-600
![]() |
Model |
HS-600 |
|
|
Input voltage range |
AC 180-264VAC or DC 254-373VDC |
||
|
DC Output |
12V 50A |
24V 25A |
|
|
Ripple&Noise |
240mv |
240mv |
|
|
Efficiency |
83% |
85% |
|
|
Over Load |
110%~150%hiccup mode,recovers automatically after fault condition is removed |
||
|
Over Voltage |
115%~135%hiccup mode,recovers automatically after fault condition is removed |
||
|
Packing |
1.17Kg/8pcs/9.8Kg |
||
|
Dimension |
240*124*65mm(L*W*H) |
||

HS-800
![]() |
Model |
HS-800 |
|
|
Input voltage range |
AC 180-264VAC or DC 254-373VDC |
||
|
DC Output |
12V 60A |
24V 33A |
|
|
Ripple&Noise |
240mv |
240mv |
|
|
Efficiency |
83% |
85% |
|
|
Over Load |
105%~150%current limiting,delay shut down o/p voltage,re-power on to recover |
||
|
Over Voltage |
115%~135%shut down o/p voltage,re-power on to recover |
||
|
Packing |
1.2Kg/8pcs/10Kg |
||
|
Dimension |
240*124*65mm(L*W*H) |
||

HS-1000
![]() |
Model |
HS-1000 |
|
|
Input voltage range |
AC 180-264VAC or DC 254-373VDC |
||
|
DC Output |
12V 80A |
24V 40A |
|
|
Ripple&Noise |
120mv |
240mv |
|
|
Efficiency |
80% |
85% |
|
|
Over Load |
105%~150%current limiting,delay shut down o/p voltage,re-power on to recover |
||
|
Over Voltage |
115%~135%shut down o/p voltage,re-power on to recover |
||
|
Packing |
2.3Kg/6pcs/16Kg |
||
|
Dimension |
291*132*68mm(L*W*H) |
||

HSE-600
![]() |
Model |
HSE-600 |
||
|
Input voltage range |
AC90-132/180-264VAC with switch selection;Or DC 254-373VDC |
|||
|
DC Output |
5.0V 100A |
12V 50A |
24V 25A |
|
|
Ripple &Noise |
240mv |
240mv |
240mv |
|
|
Efficiency |
78% |
83% |
87% |
|
|
Over Load |
105%~150%current limiting,delay shut down o/p voltage,re-power on to recover |
|||
|
Over Voltage |
115%~135%shut down o/p voltage,re-power on to recover |
|||
|
Packing |
1.8Kg/6pcs/12.5Kg |
|||
|
Dimension |
247*127*63.5mm(L*W*H) |
|||

HSCN-600
![]() |
Model |
HSCN-600 |
||
|
Input voltage range |
AC90-132/180-264VAC with switch selection;Or DC 254-373VDC |
|||
|
DC Output |
5.0V 100A |
12V 50A |
24V 25A |
|
|
Ripple&Noise |
100mv |
120mv |
240mv |
|
|
Efficiency |
76% |
80% |
85% |
|
|
Over Load |
105%~150%current limiting,delay shut down o/p voltage,re-power on to recover |
|||
|
Over Voltage |
115%~135%shut down o/p voltage,re-power on to recover |
|||
|
Packing |
2.3Kg/6pcs/16Kg |
|||
|
Dimension |
291*132*68mm(L*W*H) |
|||

HSCN-800
![]() |
Model |
HSCN-800 |
|
|
Input voltage range |
AC90-132/180-264VAC with switch selection;Or DC 254-373VDC |
||
|
DC Output |
12V 66A |
24V 33A |
|
|
Ripple &Noise |
150mv |
240mv |
|
|
Efficiency |
80% |
85% |
|
|
Over Load |
105%~150%current limiting,delay shut down o/p voltage,re-power on to recover |
||
|
Over Voltage |
115%~135%shut down o/p voltage,re-power on to recover |
||
|
Packing |
2.3Kg/6pcs/16Kg |
||
|
Dimension |
291*132*68mm(L*W*H) |
||

HSCN-1200
![]() |
Model |
HSCN-1200 |
||
|
Input voltage range |
AC 180-264VAC or DC 254-373VDC |
|||
|
DC Output |
5.0V 180A |
12V 100A |
24V 50A |
|
|
Ripple&Noise |
100mv |
120mv |
240mv |
|
|
Efficiency |
76% |
83% |
85% |
|
|
Over Load |
105%~150% current limiting,recovers automatically after fault condition is removed |
|||
|
Over Voltage |
115%~135% shut down o/p voltage,re-power on to recover |
|||
|
Packing |
4.5Kg/2pcs/10Kg |
|||
|
Dimension |
291*132*132mm(L*W*H) |
|||

HSCN-1500
![]() |
Model |
HSCN-1500 |
|
|
Input voltage range |
AC 180-264VAC or DC 254-373VDC |
||
|
DC Output |
12V 125A |
24V 62.5A |
|
|
Ripple&Noise |
120mv |
240mv |
|
|
Efficiency |
83% |
85% |
|
|
Over Load |
105%~150% current limiting,recovers automatically after fault condition is removed |
||
|
Over Voltage |
115%~135% shut down o/p voltage,re-power on to recover |
||
|
Packing |
4.5Kg/2pcs/10Kg |
||
|
Dimension |
291*132*132mm(L*W*H) |
||


JDG4-0.5 type voltage transformer,Accuracy class 0.5,designed for voltage measurement and relay protection in indoor AC circuits