Built to perform where standard power supplies cannot, this waterproof unit is designed for resilience. The cornerstone of its design is the robust IP67-rated housing, which ensures reliable operation even when exposed to splashing water, rain, dust-laden air, or temporary submersion. This high level of ingress protection makes it a versatile solution for outdoor installations, food processing areas, wash-down environments, and dusty industrial settings.
Beyond its tough exterior, the power supply delivers efficient and stable performance. It operates across a wide ambient temperature range of -10°C to +70°C, providing consistent power through seasonal changes and daily temperature swings. Its compact and efficient design minimizes heat generation and saves valuable space in enclosures or directly at the point of load. To maximize its operational lifespan, it is recommended to maintain the load between 20% and 80% of its rated capacity, and to avoid installing it in direct sunlight or adjacent to other significant heat sources whenever possible.
For safety and longevity, correct installation remains crucial. While the unit itself is sealed, its metal casing must be properly grounded to prevent any risk of electric shock. The universal AC input (e.g., 100-240VAC) allows for flexible global use. When making electrical connections, carefully follow the terminal markings to avoid reverse polarity and ensure all wiring terminals are securely tightened. A loose connection is a common cause of failure, leading to dangerous overheating points even on a fully sealed unit.
Every unit is validated through a rigorous 100% full-load burn-in test before shipment, guaranteeing it can handle real-world demands from day one. Comprehensive electronic protections against short circuits, overloads, and over-voltage conditions are integrated to safeguard both the power supply and your connected equipment from electrical faults.
Backed by a 3-year warranty, this Single Output Waterproof Power Supply offers a dependable, maintenance-friendly power solution for applications that require durability as much as they require stable voltage.
Features
●High efficiency,high reliability,small size
●Working Temp-10℃~70℃
●100% full load burn-in test
●Waterproof grade:IP67
●Protections:short circuit/over load/over voltage
●3 year warranty
HVU-50
|
|
Model |
HVU-50 |
||
|
Input voltage range |
AC85-264VAC or DC 125-373VDC |
|||
|
DC Output |
12V 4.2A |
24V 2.1A |
48V 1.1A |
|
|
Ripple&Noise |
120mv |
120mv |
200mv |
|
|
Efficiency |
82% |
84% |
88% |
|
|
Over Load |
110%~150% hiccup mode,recovers automatically after fault condition is removed |
|||
|
Over Voltage |
115%~135% hiccup mode,recovers automatically after fault condition is removed |
|||
|
Packing |
0.45Kg/30pcs/14.5Kg |
|||
|
Dimension |
170*49*34mm(L*W*H) |
|||

HVU-60
|
|
Model |
HVU-60 |
||
|
Input voltage range |
AC 85-264VAC or DC 125-373VDC |
|||
|
DC Output |
12V 5.0A |
24V 2.5A |
48V 1.3A |
|
|
Ripple&Noise |
120mv |
120mv |
200mv |
|
|
Efficiency |
82% |
84% |
88% |
|
|
Over Load |
110%~150% hiccup mode,recovers automatically after fault condition is removed |
|||
|
Over Voltage |
115%~135% hiccup mode,recovers automatically after fault condition is removed |
|||
|
Packing |
0.45Kg/30pcs/14.5Kg |
|||
|
Dimension |
170*49*34mm(L*W*H) |
|||

HVH-100
|
|
Model |
HVH-100 |
||
|
Input voltage range |
AC 85-264VAC or DC 125-373VDC |
|||
|
DC Output |
12V 8.3A |
24V 4.2A |
48 V2.1A |
|
|
Ripple&Noise |
120mv |
120mv |
200mv |
|
|
Efficiency |
84% |
86% |
89% |
|
|
Over Load |
110%~150% hiccup mode,recovers automatically after fault condition is removed |
|||
|
Over Voltage |
115%~135% hiccup mode,recovers automatically after fault condition is removed |
|||
|
Packing |
0.65KG/30PCS/20.5KG |
|||
|
Dimension |
190*49*34mm(L*W*H) |
|||

HVH-120
|
|
Model |
HVH-120 |
||
|
Input voltage range |
AC 85-264VAC or DC 125-373VDC |
|||
|
DC Output |
12V 10A |
24V 5.0A |
48V 2.5A |
|
|
Ripple&Noise |
100mv |
120mv |
200mv |
|
|
Efficiency |
84% |
86% |
89% |
|
|
Over Load |
110%~150% hiccup mode,recovers automatically after fault condition is removed |
|||
|
Over Voltage |
115%~135% hiccup mode,recovers automatically after fault condition is removed |
|||
|
Packing |
0.65KG/30PCS/20.5KG |
|||
|
Dimension |
190*49*34mm(L*W*H) |
|||
HVH-150
|
|
Model |
HVH-150 |
||
|
Input voltage range |
AC 176-264VAC or DC 254-373VDC |
|||
|
DC Output |
12V 12.5A |
24V 6.3A |
48V 3.3A |
|
|
Ripple &Noise |
200mv |
200mv |
200mv |
|
|
Efficiency |
90% |
91% |
93% |
|
|
Over Load |
110%~150% hiccup mode,recovers automatically after fault condition is removed |
|||
|
Over Voltage |
115%~135% hiccup mode,recovers automatically after fault condition is removed |
|||
|
Packing |
0.65KG/30PCS/20.5KG |
|||
|
Dimension |
190*49*34mm(L*W*H) |
|||

HVH-200
|
|
Model |
HVH-200 |
||
|
Input voltage range |
AC 176-264VAC or DC 254-373VDC |
|||
|
DC Output |
12V 16.5A |
24V 8.3A |
48V 4.2A |
|
|
Ripple&Noise |
200mv |
200mv |
200mv |
|
|
Efficiency |
90% |
91% |
93% |
|
|
Over Load |
110%~150% hiccup mode,recovers automatically after fault condition is removed |
|||
|
Over Voltage |
115%~135% hiccup mode,recovers automatically after fault condition is removed |
|||
|
Packing |
0.85KG/16PCS/14KG |
|||
|
Dimension |
205*69*43mm(L*W*H) |
|||

HVH-250
|
|
Model |
HVH-250 |
||
|
Input voltage range |
AC 180-264VAC or DC 254-373VDC |
|||
|
DC Output |
12V 20A |
24V 10A |
48V 5.0A |
|
|
Ripple&Noise |
200mv |
200mv |
200mv |
|
|
Efficiency |
90% |
91% |
93% |
|
|
Over Load |
110%~150% current limiting,recovers automatically after fault condition is removed |
|||
|
Over Voltage |
115%~135% shut down o/p voltage,re-power on to recover |
|||
|
Packing |
0.85KG/16PCS/14KG |
|||
|
Dimension |
205*69*43mm(L*W*H) |
|||

HVH-300
|
|
Model |
HVH-300 |
||
|
Input voltage range |
AC 180-264VAC or DC 254-373VDC |
|||
|
DC Output |
12V 25A |
24V 12.5A |
48V 6.25A |
|
|
Ripple &Noise |
200mv |
200mv |
200mv |
|
|
Efficiency |
90% |
91% |
93% |
|
|
Over Load |
110%~150%current limiting,recovers automatically after fault condition is removed |
|||
|
Over Voltage |
115%~135%shut down o/p voltage,re-power on to recover |
|||
|
Packing |
1.26KG/16PCS/21.5KG |
|||
|
Dimension |
240*69*43mm(L*W*H) |
|||

HVH-350
|
|
Model |
HVH-350 |
|
|
Input voltage range |
AC 180-264VAC or DC 254-373VDC |
||
|
DC Output |
24V 14.6A |
48V 7.3A |
|
|
Ripple&Noise |
200mv |
200mv |
|
|
Efficiency |
87% |
89% |
|
|
Over Load |
110%~150%current limiting,recovers automatically after fault condition is removed |
||
|
Over Voltage |
115%~135%shut down o/p voltage,re-power on to recover |
||
|
Packing |
1.26KG/16PCS/21.5KG |
||
|
Dimension |
240*69*43mm(L*W*H) |
||

HVH-400
|
|
Model |
HVH-400 |
|
|
Input voltage range |
180~264VAC 47~63Hz;254~370VDC |
||
|
DC Output |
24V 16.5A |
48V 8.3A |
|
|
Ripple&Noise |
200mVp-p |
200mVp-p |
|
|
Efficiency |
92% |
94% |
|
|
Over Load |
105%~135% |
||
|
Protection mode:Current limiting,automatic recovery after abnormal conditions are removed. |
|||
|
Over Voltage |
115%~135% |
||
|
Protection mode:Hiccup mode,automatic recovery after abnormal conditions are removed. |
|||
|
Packing |
1.26Kg/16pcs/21.5Kg |
||
|
Dimension |
240*69*43mm(L*W*H) |
||

HVH-500
|
|
Model |
HVH-500 |
|||
|
Input voltage range |
AC 180-264VAC or DC255-373VDC |
||||
|
DC Output |
12V |
24V |
36V |
48V |
|
|
Ripple &Noise |
200mVp-p |
200mVp-p |
200mVp-p |
200mVp-p |
|
|
Efficiency |
89% |
90.5% |
91% |
91% |
|
|
Over Load |
Overload protection activates at 105%to 135%of the rated output power during startup. |
||||
|
Protection mode:Current limiting,automatic recovery after the abnormal load condition is removed. |
|||||
|
Over Voltage |
15~17V |
30~32V |
42~44V |
42~44V 55.2-64.8V |
|
|
Protection mode:Hiccup mode,automatic recovery after the abnormal condition is removed. |
|||||
|
Packing |
2.05Kg/10pcs/21.5Kg |
||||
|
Dimension |
205*120*56mm(L*W*H) |
||||

LPV-12
|
|
Model |
LPV-12 |
||
|
input voltage range |
AC90-264VAC or DC 125-373VDC |
|||
|
DC Output |
12V 1.0A |
24V 0.5A |
48V 0.25A |
|
|
Ripple &Noise |
120mv |
120mv |
200mv |
|
|
Efficiency |
81% |
83% |
84% |
|
|
Over Load |
110%~150%hiccup mode,recovers automatically after fault condition is removed |
|||
|
Over Voltage |
/ |
|||
|
Packing |
0.22Kg/60pcs/14Kg |
|||
|
Dimension |
118*35*26mm(L*W*H) |
|||

LPV-20
|
|
Model |
LPV-20 |
||
|
Input voltage range |
AC 90-264VAC or DC 125-373VDC |
|||
|
DC Output |
12V 1.67A |
24V 0.84A |
48V 0.42A |
|
|
Ripple&Noise |
120mv |
120mv |
200mv |
|
|
Efficiency |
81% |
83% |
84% |
|
|
Over Load |
110%~150%current limiting,recovers automatically after fault condition is removed |
|||
|
Over Voltage |
/ |
|||
|
Packing |
0.22Kg/60pcs/14Kg |
|||
|
Dimension |
118*35*26mm(L*W*H) |
|||

LPV-35
|
|
Model |
LPV-35 |
||
|
Input voltage range |
AC90-264VAC or DC 125-373VDC |
|||
|
DC Output |
12V 3.0A |
24V 1.5A |
48V 0.8A |
|
|
Ripple&Noise |
120mv |
120mv |
200mv |
|
|
Efficiency |
81% |
83% |
84% |
|
|
Over Load |
110%~150%hiccup mode,recovers automatically after fault condition is removed |
|||
|
Over Voltage |
115%~135%hiccup mode,recovers automatically after fault condition is removed |
|||
|
Packing |
0.34Kg/60pcs/22Kg |
|||
|
Dimension |
148*40*30mm(L*W*H) |
|||

LPV-60
|
|
Model |
LPV-60 |
||
|
Input voltage range |
AC90-264VAC or DC 125-373VDC |
|||
|
DC Output |
12V 5.0A |
24V 2.5A |
48V 1.3A |
|
|
Ripple &Noise |
120mv |
120mv |
200mv |
|
|
Efficiency |
81% |
83% |
84% |
|
|
Over Load |
110%~150%hiccup mode,recovers automatically after fault condition is removed |
|||
|
Over Voltage |
115%~135%hiccup mode,recovers automatically after fault condition is removed |
|||
|
Packing |
0.4Kg/60pcs/25Kg |
|||
|
Dimension |
162*42*32mm(L*W*H) |
|||

LPV-100
|
|
Model |
LPV-100 |
||
|
Input voltage range |
AC90-264VAC or DC 125-373VDC |
|||
|
DC Output |
12V 8.3A |
24V 4.2A |
48V 2.1A |
|
|
Ripple&Noise |
120mv |
120mv |
200mv |
|
|
Efficiency |
81% |
83% |
84% |
|
|
Over Load |
110%~150%hiccup mode,recovers automatically after fault condition is removed |
|||
|
Over Voltage |
115%~135%hiccup mode,recovers automatically after fault condition is removed |
|||
|
Packing |
0.62Kg/20pcs/13.5Kg |
|||
|
Dimension |
190*53*37mm(L*W*H) |
|||


JDG4-0.5 type voltage transformer,Accuracy class 0.5,designed for voltage measurement and relay protection in indoor AC circuits